TM 9-2320-365-20-1  CONTINUITY TEST  Change 2 2-949  (1) Set multimeter to ohms.  (2) Connect positive (+) probe of multimeter to  winch in solenoid L4 terminal 2.  (3) Connect negative (-) probe of multimeter to  ground and note reading on multimeter.  (4) If continuity is not present, repair wire 3069  (para 2-40) or replace winch control valve  cable assembly (para 7-85).  (5) If continuity is present, replace winch control  valve assembly (para 17-6).  (6) Connect winch in solenoid L4 connector on  solenoid L4 and tighten screw.