TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download

Page 1365 of 1760

TM 9-2320-365-20-1 CONTINUITY TEST Change 2 2-949 (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to winch in solenoid L4 terminal 2. (3) Connect negative (-) probe of multimeter to ground and note reading on multimeter. (4) If continuity is not present, repair wire 3069 (para 2-40) or replace winch control valve cable assembly (para 7-85). (5) If continuity is present, replace winch control valve assembly (para 17-6). (6) Connect winch in solenoid L4 connector on solenoid L4 and tighten screw.