e86. 11K SELF-RECOVERY WINCH DOES NOT REEL IN INITIAL SETUP Equipment Condition Engine shut down (TM 9-2320-365-10). Personnel Required (2) References TM 9-4910-571-12&P Tools and Special Tools Tool Kit, Genl Mech (Item 44, Appendix C) STE/ICE-R (Item 39, Appendix C) Multimeter, Digital (Item 22, Appendix C) Wrench, Torque, 0-200 lb-in. (Item 58, Appendix C) Materials/Parts Wire, Elect, 50 ft (Item 77, Appendix D) KNOWN INFO 1. WARNING Read WARNING on following page. START TEST OPTIONS Voltage Test or STE/ICE-R Test #89 REASON FOR QUESTION This question eliminates possible problems and determines where troubleshooting continues. YES NO Go to step 3 of this fault. TM 9-2320-365-20-1 Is 24 VDC present on winch in solenoid L4 connector terminal 1? Circuit breaker OK. 11K self-recovery winch pays out. POSSIBLE PROBLEMS Faulty winch control valve cable assembly. Faulty winch control valve assembly. Faulty WINCH IN/OUT switch. Faulty PTO cable assembly. Faulty auxiliary panel cable assembly. 2-946 Change 2