TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download

Page 1355 of 1760

TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 2-939 2-939 2-939 2-939 2-939 CONTINUITY TEST (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to connector P110-J. (3) Connect negative (-) probe of multimeter to connector P113-A and note reading on multimeter. (4) If continuity is not present, replace CTIS cable assembly (para 7-53). (5) If continuity is present, replace manifold valve assembly (para 12-7). (6) Connect connector P113 to manifold valve assembly. (7) Install kick panel (para 16-3). (8) Connect connector P110 to CTIS ECU.