TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download
Page 1345 of 1760
TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1  2-929 2-929 2-929 2-929 2-929  CONTINUITY TEST  (1) Set multimeter to ohms.  (2) Connect positive (+) probe of multimeter to  connector P110-J.  (3) Connect negative (-) probe of multimeter to  connector P113-A and note reading on  multimeter.  (4) If continuity is not present, replace CTIS cable  assembly (para 7-53).  (5) If continuity is present, replace manifold valve  assembly (para 12-7).  (6) Connect connector P113 to manifold valve  assembly.  (7) Install kick panel (para 16-3).  (8) Connect connector P110 to CTIS ECU.