TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download

Page 1341 of 1760

TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 2-925 2-925 2-925 2-925 2-925 CONTINUITY TEST CONTINUITY TEST (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to connector P110-R. (3) Connect negative (-) probe of multimeter to connector P112-D and note reading on multimeter. (4) If continuity is not present, replace CTIS cable assembly (para 7-53). (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to connector P110-F. (3) Connect negative (-) probe of multimeter to connector P112-B and note reading on multimeter. (4) If continuity is not present, replace CTIS cable assembly (para 7-53). (5) Connect connector P112 to manifold valve assembly.