TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download
Page 1333 of 1760
TM 9-2320-365-20-1 CONTINUITY TEST Change 2 2-918.19 (1) Connect connector P110 to CTIS ECU. (2) Remove kick panel (para 16-3). (3) Remove circuit breaker CB40 from PDP. (4) Disconnect connector P111 from connector J111. (5) Set multimeter to ohms. (6) Connect positive (+) probe of multimeter to connector J111 socket E. (7) Connect negative (-) probe of multimeter to circuit breaker CB40 socket 7 and note reading on multimeter. (8) If continuity is not present, repair wire 1911 from connector J111 socket E to circuit breaker CB40 socket 7 (para 2-40) or replace WTEC II dashboard cable assembly (para 7-10) or WTEC III dashboard cable assembly (para 7-11). (9) If continuity is present, replace CTIS cable assembly (para 7-53). (10) Install circuit breaker CB40 on PDP. (11) Connect connector J111 to connector P111. (12) Install kick panel (para 16-3).