TM 9-2320-365-20-1 Change 2 2-918.7 RESISTANCE TEST (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to pressure transducer connector pin C. (3) Connect negative (-) probe of multimeter to pressure transducer connector pin A and note reading on multimeter. (4) If 1-50 ohms resistance is not present, replace pressure transducer (para 12-7).