TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download

Page 1319 of 1760

TM 9-2320-365-20-1 Change 2 2-918.5 RESISTANCE TEST RESISTANCE TEST (1) Disconnect connector P113 from pressure transducer connector. (2) Set multimeter to ohms. (3) Connect positive (+) probe of multimeter to pressure transducer connector pin A. (4) Connect negative (-) probe of multimeter to pressure transducer connector pin B and note reading on multimeter. (5) If 1-50 ohms resistance is not present, replace pressure transducer (para 12-7). (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to pressure transducer connector pin B. (3) Connect negative (-) probe of multimeter to pressure transducer connector pin C and note reading on multimeter. (4) If 1-50 ohms resistance is not present, replace pressure transducer (para 12-7).