TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download

Page 1288 of 1760

TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 2-892 2-892 2-892 2-892 2-892 1. START YES NO Chemical detector indicator operates. If 12 vdc is not present, wire 1803 is faulty. KNOWN INFO POSSIBLE PROBLEMS WARNING Read WARNING on following page. TEST OPTIONS Voltage Test or STE/ICE-R #89 REASON FOR QUESTION Is 12 vdc present at terminal lug TL97? Go to step 3 of this fault. Faulty dashboard cable assembly. Faulty chemical alarm kit cable assembly. Faulty chemical alarm. e80. CHEMICAL ALARM DOES NOT OPERATE INITIAL SETUP Equipment Condition Engine shut down (TM 9-2320-365-10). Personnel Required (2) Tools and Special Tools Tool Kit, Genl Mech (Item 44, Appendix C) STE/ICE-R (Item 39, Appendix C) Multimeter, Digital (Item 22, Appendix C) References TM 9-4910-571-12&P