TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download

Page 123 of 1760

TM 9-2320-365-20-1 Change 2 2-47 Table 2-1. Preventive Maintenance Checks and Services (Cont) Item No. Interval Location Item to be Checked or Serviced Procedure Not Fully Mission Capable If: 43 Semiannual FUEL/ WATER SEPARA- TOR a. Inspect fuel/water separator assembly for dents and cracks that could cause leaks. b. Deleted. a. Any leak is evident.