TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download
Page 1228 of 1760
TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1  2-832 2-832 2-832 2-832 2-832  1.  START  YES  NO  Circuit breaker OK.  Main instrument panel  controls and indicators OK.  This question eliminates  possible problems and  determines where  troubleshooting continues.  KNOWN INFO  POSSIBLE PROBLEMS  WARNING  Read WARNING  on following page.  Go to step 5 of this fault.  TEST OPTIONS  Voltage Test or  STE/ICE-R #89  REASON FOR QUESTION  Is 24 vdc present at heater  fan control switch blue  wire?  Faulty heater fan control  switch.  Faulty personnel heater.  Faulty dashboard cable  assembly.  e73. PERSONNEL HEATER FAN DOES NOT OPERATE  INITIAL SETUP  Equipment Condition  Engine shut down (TM 9-2320-365-10).  Personnel Required  (2)  References  TM 9-4910-571-12&P  Tools and Special Tools  Tool Kit, Genl Mech (Item 44, Appendix C)  STE/ICE-R (Item 39, Appendix C)  Multimeter, Digital (Item 22, Appendix C)