Change 1 2-757  TM 9-2320-365-20-1  CAUTION  Use care when testing electrical connectors.  Do not damage connector pins or sockets  with multimeter probes. Failure to comply  may result in damage to equipment.  NOTE  Inspect connector pins/sockets for damage,  corrosion, and serviceability. Check that  connector pins are not pushed back and  are capable of making good contact.  CONTINUITY TEST  (1) Remove three screws and washers from  PDP.  (2) Remove three screws from PDP.  (3) Lift PDP outward to gain access.  (4) Disconnect connector J51 from connector  P51.  (5) Set multimeter to ohms.  (6) Connect positive (+) probe of multimeter  to relay K28 terminal 87 on PDP.  (7) Connect negative (-) probe of multimeter  to connector J51 pin 9 and note reading  on multimeter.  (8) If continuity is not present, repair wire  489T from relay K28 terminal 87 on PDP  to connector J51 pin 9 (para 2-40) or  replace WTEC II dashboard assembly  (para 7-10) or WTEC III dashboard cable  assembly (para 7-11).  (9) Install relay K28 in PDP.