VOLTAGE TEST  CAUTION  Change 1 2-753  TM 9-2320-365-20-1  Use care when testing electrical connectors.  Do not damage connector pins or sockets  with multimeter probes. Failure to comply  may result in damage to equipment.  NOTE  CONTINUITY TEST  Inspect connector pins/sockets for damage,  corrosion, and serviceability. Check that  connector pins are not pushed back and  are capable of making good contact.  WARNING  Remove rings, bracelets, watches, necklaces,  and any other jewelry before working around  vehicle. Jewelry can catch on equipment and  cause injury or short across electrical circuits  and cause severe burns or electrical shock.  (1) Set multimeter to volts DC.  (2) Connect positive (+) probe of multimeter  to relay K28 terminal 30 on PDP.  (3) Connect negative (-) probe of multimeter  to ground.  (4) Position main light switch to SER DRIVE  (TM 9-2320-365-10) and note reading  on multimeter.  (5) If 24 VDC is not present, repair wire 1957  from K28 terminal 30 on PDP to circuit  breaker CB41 terminal 2 (para 2-40) or  replace WTEC II dashboard cable  assembly (para 7-10) or WTEC III  dashboard cable assembly (para 7-11).  (6) Position main light switch to OFF  (TM 9-2320-365-10).  (1) Remove PDP cover (para 16-2).  (2) Remove relay K28 from PDP.  (3) Set multimeter to ohms.  (4) Connect positive (+) probe of multimeter  to connector J130 socket E.  (5) Connect negative (-) probe of multimeter  to relay K28 terminal 87 on PDP and note  reading on multimeter.  (6) If continuity is not present, go to step 6  of this fault.