TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 2-745 2-745 2-745 2-745 2-745 CONTINUITY TEST (1) Remove instrument panel assembly for access (para 7-15). (2) Disconnect connector PX15 from main light switch. (3) Connect positive (+) probe of multimeter to connector PX15-K. (4) Connect negative (-) probe of multimeter to PDP, terminal 87, where relay K6 was removed, and note reading on multimeter. (5) If continuity is not present, repair wire 1404 (para 2-40) or replace WTEC II dashboard cable assembly (para 7-10) or WTEC III dashboard cable assembly (para 7-11). (6) If continuity is present, replace relay K6 (para 7-9). (7) Install relay K6 in PDP. (8) Install PDP cover (para 16-2). (9) Connect connector PX15 to main light switch. (10) Install instrument panel assembly (para 7-15).