CONTINUITY TEST (1) Remove WTEC III relay K34 from PDP. (2) Set multimeter to ohms. (3) Connect positive (+) probe of multimeter to PDP, where WTEC III relay K34 terminal 86 was removed. (4) Connect negative (-) probe of multimeter to PDP, where WTEC III relay K25 terminal 86 was removed, and note reading on multimeter. (5) If continuity is not present, repair wire 146 from WTEC III relay K34 terminal 86 to WTEC III relay K25 terminal 86 (para 2-40) or replace WTEC III dashboard cable assembly (para 7-11). (6) Install WTEC III relay K34 on PDP. TM 9-2320-365-20-1 Change 1 2-665