TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download
Page 1039 of 1760
CONTINUITY TEST  CAUTION  Use care when testing electrical connectors.  Do not damage connector pins or sockets  with multimeter probes. Failure to comply  may result in damage to equipment.  NOTE  Inspect connector pins/sockets for damage,  corrosion, and serviceability. Check that  connector pins are not pushed back and  are capable of making good contact.  Change 1 2-653  TM 9-2320-365-20-1  (1) Remove instrument panel assembly for  access (para 7-15).  (2) Disconnect connector J114 from WTEC II  TEPSS.  (3) Loosen screw in connector J116.  (4) Disconnect connector J116 from WTEC II  VIM.  (5) Connect positive (+) probe of multimeter to  connector J116 socket F2.  (6) Connect negative (-) probe of multimeter to  connector J114 socket 13 and note reading  on multimeter.  (7) If continuity is not present, replace WTEC II  cab transmission harness (para 7-86).  (8) Connect connector J114 to WTEC II TEPSS.  (9) Install instrument panel assembly (para 7-15).  (10) Connect connector J116 to WTEC II VIM.  (11) Tighten screw in connector J116.