TM 9-2320-365-10 Change 2 3-70.13 Table 3-2. Troubleshooting (Cont) MALFUNCTION TEST OR INSPECTION CORRECTIVE ACTION u3. NO POWER TO ENHANCED POSITION LOCATION REPORTING SYSTEM (EPLRS). Remove rings, bracelets, wristwatches, neck chains, and any other jewelry before working around vehicle. Jewelry may catch on equipment or may short across an electrical circuit. Failure to comply may result in serious injury or death to personnel. Step 1. Check to see if circuit breaker (CB5) is tripped. (a) Remove wing screw from power distribution shelf. (b) Loosen wing screw on electrical distribution block cover. (c) Remove electrical distribution block cover from power distribution shelf. (d) Check to see if circuit breaker (CB5) is tripped. If circuit breaker (CB5) is tripped, push reset button in to reset. If circuit breaker (CB5) trips again, notify Unit Maintenance. WARNING