TM-9-2320-365-10 LMTV Operator Manual M1078 Series Download
Page 617 of 836
TM 9-2320-365-10 Table 3-2. Troubleshooting (Cont) MALFUNCTION TEST OR INSPECTION CORRECTIVE ACTION r. 11K SELF-RECOVERY WINCH (SRW) SYSTEM r1. 11K SELF-RECOVERY WINCH (SRW) DOES NOT OPERATE. NOTE Hydraulic oil level gage should read two marks past the 3/4 mark during a cold check. This is a normal reading. Do not overfill reservoir. Step 1. Check hydraulic oil level gage to determine hydraulic oil level. If oil level is low, add hydraulic oil (Appendix F). Step 2. Check hydraulic lines and fittings for Class III leaks. If Class III leaks are found or 11K SRW still does not operate, notify Unit Maintenance. Change 1 3-70.9