TM-9-2320-365-10 LMTV Operator Manual M1078 Series Download
Page 304 of 836
TM 9-2320-365-10  2-24. LIGHT MATERIAL HANDLING CRANE (LMHC) OPERATION  (CONT)  WARNING  Ensure that engine is not running before disconnecting circuit breaker box NATO  connector at vehicle NATO connector. Failure to comply may result in serious  injury or death to personnel.  CAUTION  Ensure that power cable does not come in contact with exhaust pipe. Failure to  comply may result in damage to equipment.  (18) Disconnect circuit breaker box NATO connector (11) from vehicle NATO connector  (12).  (19) Install dust cap (13) on vehicle NATO connector (12).  (20) Install dust cap (14) on circuit breaker box NATO connector (11).  (21) Disconnect power cable connector (15) from circuit breaker box NATO connector  (16).  (22) Install dust cap (17) on circuit breaker box NATO connector (16).  (23) Install dust cap (18) on power cable connector (15).  2-204