TM-9-2320-365-10 LMTV Operator Manual M1078 Series Download
Page 236 of 836
TM 9-2320-365-10 2-21. VEHICLE OPERATION (CONT) CAUTION • Do not press ether start switch unless engine is cranking. Failure to comply may result in damage to engine. • Do not use ether after the engine has reached idle speed (750 rpm) and is no longer in danger of stalling. Failure to comply may result in damage to engine. NOTE • Continue to inject ether if engine has started but will not run without ether. • If outside air temperature is 32° F to -25° F (0° C to -32° C) perform step (6) and (7). (7) Press and hold ether start switch (8) for approximately three seconds and release for two seconds. (8) Repeat step (7) until engine has started, engine speed has increased over cranking speed, and engine maintains speed. 2-136 Change 1