TM 9-2320-365-10 Table 2-1. Preventive Maintenance Checks and Services (All Models) (Cont) Location Item No. Interval Item to Check/ Service Crewmember Procedure Not Fully Mission Capable If: WARNING • Lead-acid battery gases can explode. Do not smoke, have open flames, or make sparks around a battery, especially if caps are off. Battery may give off gas which can explode. Failure to comply may result in serious injury or death to personnel. • Remove rings, bracelets, wristwatches, neck chains, and any other jewelry before working around vehicle. Jewelry may catch on equipment or may short across and electrical circuit. Failure to comply may result in injury to personnel. CAUTION When operating in outside temperatures above 90°F (32°C), battery fluid levels must be checked daily. Failure to comply may result in damage to equipment. 48 Weekly Batteries a. Open battery cover (para 3-8a). b. Check batteries for damaged casing, terminal posts, and security of mounting. Check that battery cable clamps are secure. Notify Unit Maintenance if any defects are found. b. One or more batteries are missing, unserviceable, or leaking. Battery cable clamps are loose. Change 1 2-71