TM-9-2990-206-34&P Parts Manual, Tools and Maintenance for Turbocharger Model T18C01 Download

Page 39 of 85

INSPECTION-Continued. INSPECT DUST DETECTOR COVER, INLET AND OUTLET ADAPTERS, AND FILTER RETAINING STRAP NOTE This procedure applies to “clean air” turbosuper- charger only. 1. 2. 3. 4. Inspect dust detector cover (A) for cracks, scoring of mating surface (B), and thread damage in tapped holes (C). Check adapters (D) and (E) for cracks, distortion or thread damage. Ensure both are clear of obstruction. Inspect filter retaining strap (F) for cracks, bends, and general serviceability. Replace any of these components if damaged. TA293547 3-16 Change 1 TM 9-2990-206-34&P