TM-9-2815-220-34 Direct Support Manual for AVDS-1790-2C and AVDS-1790-2D Engines Download
Page 493 of 532
) (7) Install retainjng strap (fig. 4-12) aJ1d secure with two capscrews and lockwashers. Install cable connector through support with connector key at the 3 o'clock position. Secure coiector with four plain nuts, lockwashers, and machine screws. PLAIN NUT, LOCKWASHER ANO MACHINE SCREW .. TA265592 Figure 4·12. Removing or Installing Starter, Smoke, and Dust Detector Electrical · Cable Connector (8) Install two retning straps (fig. 4-13) and secure two loop clamps ru1d mounting bracket with four capscrews and lockwashers. 4-7. Dust Ejector System. a. Removal. NOTE Similar procedures are required to re- move the left and right dust ejector systems. For instructional purposes, re- moval of the left bank dust ejector system is described. Removal procedures for the right bank dust ejector system are similar except for the engine breather tube and transmission breather tube. (1) Left bank. (a) Loosen two hose clamps (fig. 4-14). Remove machine bolt and self-locking nut from loop clamp and bracket. Remove loop clamp. Remove six self-locking nuts and remove ejector tube. Remove and discard gasket. TM 9-2815·220-34 CAP S CREW AND LOCKWASHER RETAINING STRAP TA265593 Figure 4·13. Removing or Installing Starter, Smoke and Dust Detector Electrical Cable (b) Remove two capscrews and self-locking nuts (fig. 4-15). Remove scavenge tube and exhaust pipe cap assembly. (2) Right bank. (a) Loosen nut (fig. 4-16) and remove transmission breather tube. Remove elbow from ejector tube. (b) Remove the right bru1k dust ejector system in a manner simHru· to paragraph (l ) above. Change 3 9