TA265586 Figure 4-6. Removing or Installing Starter and Dust Detector Electrical Cable (3) Cut and remove two tie wraps (fig. 4-7). (4) Remove two self-locking nuts (fig. 4-8) and two loop clamps. Remove two clamps from electrical leads. Disconnect two electrical connect- ors from solenoid valves. Remove self-locking nut and capscrew securing ground lead to solenoid valve bracket. SELF-LOCKING NUT AND CAPSCREW K O BRACKET \ I '. TM 9-2815-220-34 (5) Disconnect and remove two air pressure hoses (fig. 4-9) from the right bank pressure switch and lurbosupercharger. Remove capscrew and lock- washer and remove pressure switch and bracket, as an assembly. (6) Remove two capscrews (fig. 4-10) and lockwashers, and separate pressure switch from bracket. Remove two adapters and remove and discard two preformed pnckings. NOTE e left bank pressure switch may be removed in a similar manner. Figure 4· 7 Removing or Installing Smoke and Dust Detector Electrical Cables LOOP CLAMP TA265588 Figure 4· 8 Removing or Installing Smoke and Dust Detector Electrical Cable Change 3 4.7