TM-9-2815-220-34 Direct Support Manual for AVDS-1790-2C and AVDS-1790-2D Engines Download
Page 200 of 532
TM 9-2815-220-34  Figurl!S-7. Remo1•i11u oi- i11sta/li11u coolingfa11s.  ASSEMBLED  WASHER BOLT  LAMP  j  ASSEMBLED  WASHER BOLT  Figu n� 3-8. Oi+co1111octi11g or com1ectingfro11t eml ef coli 11g}i111  shroud.  3-8.1. Time Totalizing Meter (Model AVDS-  1790-2DR)  a. Disconnect electrical lead (1, fig. 3-10.1) from  time totalizing meter and generator. Remove two  capscrews and lockwashers (2) and remove cush-  ioned clamps.  b. Remove four self-locking nuts (3) and remove  ground lead (4), spacer (5), lime t o talizing meter  (6), and electrical lead ( 1 ).  c. Install the lower two self-locking nuts (3) to  secure the lifting eye to the damper housing.  d. Remove two upper self-locking nuts on left  damper housing lifting eye and remove spacer.  3-6  Change 3  I Assembled washer bolt, llnt  wnsher and hexagon nut  2 Assembled washer bolt  f'it1u 1·r .�-9. Re111uvi 11g or i 11slutli 11 cooling fan sltrou,  moclel A \IDS-J 790-2C a n  \IDS· 1790·2D e11gi nes.  3-9. Oil Coolers and Support Frames  <1. Oil Coolers.  (1) Remove two assembled washer bolts ( 1,  fig. 3-J I) securing oil cooler vent lfoe clamps to  shroud. Disconnect oil cooler vent Jines (2) at oil  cooler vent adapter (3), oil cooler vent tee (4) and  I at damper housing vent adapter (5) and remove  vent lines and four cushioned clamps. Remove  cushfoned clamps from lines and disconnect lines  from tee. Disco1ect fuel filler cons tan l bleed hose  (6) at bulkhead union (7),  )  )