TM-9-2815-220-24 Maintenance Manual for AVDS-1790-2CA AVDS-1790-DA and AVDS-1790-2DR Engines Download

Page 900 of 1563

TM 9-2815-220-24 PTO COUPLING/FUEL PUMP DRIVE HOUSING REPAIR (2DR ONLY) 0111 00 INSTALLATION (Continued) NOTE Drive coupling taper and spur gear shaft taper areas must be wiped dry with cleaning compound to assure maximum friction. 2. Install PTO drive coupling (4). WARNING Cleaning solvent is mildly toxic. Solvent evaporates and both the fumes and liquid are flammable. Continued contact with solvent can cause skin problems. Ensure there is good airflow when using solvent, and work area is away from heat and flames. Keep fire extinguisher nearby. Do not breathe solvent fumes. Avoid skin contact. See Warning in front of Manual. a. Prepare spur gear shaft (31) by wiping clean and dry using cleaning compound (item 8, WP 0173) with a shop cloth (item 26, WP 0173). b. Place coupling (4) onto shaft (31). c. Carefully lubricate (item 23, WP 0173) gear shaft (31) threads making sure that taper on both parts remains clean and dry. 4 31 WP 0111 00-10