TM-9-2815-220-24 Maintenance Manual for AVDS-1790-2CA AVDS-1790-DA and AVDS-1790-2DR Engines Download
Page 760 of 1563
TM 9-2815-220-24 SMOKE GENERATION SYSTEM REPLACEMENT 0094 00 INSTALLATION (Continued) 10. Install smoke generator fuel line (1). a. Install smoke generator fuel line (1) at tee fitting (2) on the bottom of the secondary fuel filter housing (3). 2 1 3 3 END OF WORK PACKAGE WP 0094 00-16