TM-9-2815-220-24 Maintenance Manual for AVDS-1790-2CA AVDS-1790-DA and AVDS-1790-2DR Engines Download
Page 753 of 1563
TM 9-2815-220-24 SMOKE GENERATION SYSTEM REPLACEMENT 0094 00 CLEANING 1. See Work Package 0028 for Standard Cleaning Procedures. INSPECTION All parts must be inspected with care. Replace part if damage or wear exceeds allowable limits. 1. See Work Package 0028 for Standard Inspection Procedures. INSTALLATION NOTE Use thread sealing product on threaded pipe connections with the exception of fuel line connections at exhaust pipes. CAUTION Use anti-seize compound (C5A or equivalent) on threaded connection between fuel lines and exhaust pipes. Failure to comply may lead to seized fittings in exhaust pipes. WP 0094 00-9