TM-9-2815-220-24 Maintenance Manual for AVDS-1790-2CA AVDS-1790-DA and AVDS-1790-2DR Engines Download

Page 720 of 1563

TM 9-2815-220-24 MANIFOLD HEATER ASSEMBLY AND RELATED PARTS REPLACEMENT 0088 00 INSTALLATION (Continued) 4. Connect left bank, fuel-into-nozzle hose (10). a. Connect hose (10) to fuel inlet solenoid (27) at damper end of engine. b. Secure hose using five clamps (25) attached to clamps (26) with screws (24) and self- locking nuts (23) (item 32, WP 0175). 5. Secure spark plug electrical lead (3) using clamp (30) fastened with screw (29) and self- locking nut (28) (item 37, WP 0175). 6. Install right bank, fuel-into-nozzle hose (31) and spark plug lead in a similar manner. 27 31 10 30 28 24 23 25 26 29 10 3 WP 0088 00-14