TM-9-2815-220-24 Maintenance Manual for AVDS-1790-2CA AVDS-1790-DA and AVDS-1790-2DR Engines Download

Page 501 of 1563

TM 9-2815-220-24 STARTER/ SMOKE GENERATOR/ DUST DETECTOR WIRING HARNESS REPLACEMENT, LVPM CRANKCASE MOUNTED (2CA, 2DA) (PN 11655456, 11682726) 0061 00 INSTALLATION (Continued) NOTE For smoke generation systems with single-solenoid configuration, harness installation instructions are covered in steps 6 and 7. For smoke generation systems with dual-solenoid configuration, harness installation instructions are covered in steps 4 and 5. 7. Install single-solenoid smoke generator harness lead (33). a. Install connector (44) at smoke generator solenoid (45). b. Install screw (46) with new lock washer (47) (item 93, WP 0175) securing ground lead (48). c. Install loop clamps (54) with assembled washer screws (53). d. Install tie wraps (49) (item 81, WP 0175) as necessary. 46, 47 48 49 45 44 33 WP 0061 00-21