TM-9-2815-220-24 Maintenance Manual for AVDS-1790-2CA AVDS-1790-DA and AVDS-1790-2DR Engines Download
Page 500 of 1563
TM 9-2815-220-24 STARTER/ SMOKE GENERATOR/ DUST DETECTOR WIRING HARNESS REPLACEMENT, LVPM CRANKCASE MOUNTED (2CA, 2DA) (PN 11655456, 11682726) 0061 00 INSTALLATION (Continued) NOTE For smoke generation systems with single-solenoid configuration, harness installation instructions are covered in steps 6 and 7. For smoke generation systems with dual-solenoid configuration, harness installation instructions are covered in steps 4 and 5. 6. Install smoke generator/dust detector leads (33, 34) and starter harnesses (27) on models with single-solenoid smoke generation system. a. Install wiring harness connectors (27) into bracket (28) using four slotted head machine screws (29), new lock washers (30) (item 91, WP 0175), and nuts (31). b. Install retaining strap (24) on starter harnesses and secure bracket assembly using two screws (25) with new lock washers (26) (item 92, WP 0175). c. Install loop clamps (42), using assembled washer screws (41) as necessary to secure smoke generator harness (33) and dust detector harness (32). d. Install tie wraps (43) (item 81, WP 0175) as necessary. 28 24 25, 26 (two places) 32 41, 42, 43 33 41, 42, 43 29, 30, 31 (four places) 27 WP 0061 00-20