Page 498 of 1563
TM 9-2815-220-24 STARTER/ SMOKE GENERATOR/ DUST DETECTOR WIRING HARNESS REPLACEMENT, LVPM CRANKCASE MOUNTED (2CA, 2DA) (PN 11655456, 11682726) 0061 00 INSTALLATION (Continued) NOTE For smoke generation systems with dual-solenoid configuration, harness installation instructions are covered in steps 4 and 5. For smoke generation systems with single-solenoid configuration, harness installation instructions are covered in steps 6 and 7. 4. Install smoke generator/dust detector leads (32, 33) and starter harnesses (27) on models with dual-solenoid smoke generation system. a. Install wiring harness connectors (27) into bracket (28) using four slotted head machine screws (29), new lock washers (30) (item 91, WP 0175), and nuts (31). b. Install retaining strap (24) on starter harnesses and secure bracket assembly using two screws (25) with new lock washers (26) (item 92, WP 0175). c. Install assembled washer screws (34), loop clamps (35) and tie wraps (36) (item 80, WP 0175) as necessary securing dust detector (32) and smoke generation harness (33). 33 32 34, 35, 36 25, 26 (two places) 24 27 29, 30, 31 (four places) 28 WP 0061 00-18