TM 9-2815-220-24 STARTER/ SMOKE GENERATOR/ DUST DETECTOR WIRING HARNESS REPLACEMENT, LVPM CRANKCASE MOUNTED (2CA, 2DA) (PN 11655456, 11682726) 0061 00 REMOVAL (Continued) 11. Remove dust detector lead (32) for both dual and single solenoid smoke generator applications. NOTE Dust detector harnesses disconnect in the same fashion between left and right bank. Only the right bank is illustrated. a. Disconnect electrical connectors (50). b. Remove screws (51) and lock washers (52) securing dust detector ground lead (53). Discard lock washers. 32 53 50 51, 52 WP 0061 00-11