TM-9-2815-220-24 Maintenance Manual for AVDS-1790-2CA AVDS-1790-DA and AVDS-1790-2DR Engines Download

Page 490 of 1563

TM 9-2815-220-24 STARTER/ SMOKE GENERATOR/ DUST DETECTOR WIRING HARNESS REPLACEMENT, LVPM CRANKCASE MOUNTED (2CA, 2DA) (PN 11655456, 11682726) 0061 00 REMOVAL (Continued) NOTE For smoke generation systems with single-solenoid configuration, harness removal instructions are covered in steps 9 and 10. For smoke generation systems with dual-solenoid configuration, harness removal instructions are covered in steps 7 and 8. 10. Remove single-solenoid smoke generator harness lead (33). a. Remove connector (44) at smoke generator solenoid (45). b. Remove screw (46) with lock washer (47) securing ground lead (48). Discard lock washer. c. Clip and remove tie wraps (49) as needed. 33 46, 47 48 49 45 44 WP 0061 00-10