TM-9-2815-220-24 Maintenance Manual for AVDS-1790-2CA AVDS-1790-DA and AVDS-1790-2DR Engines Download
Page 488 of 1563
TM 9-2815-220-24 STARTER/ SMOKE GENERATOR/ DUST DETECTOR WIRING HARNESS REPLACEMENT, LVPM CRANKCASE MOUNTED (2CA, 2DA) (PN 11655456, 11682726) 0061 00 REMOVAL (Continued) NOTE For smoke generation systems with dual-solenoid configuration, harness removal instructions are covered in steps 7 and 8. For smoke generation systems with single-solenoid configuration, harness removal instructions are covered in steps 9 and 10. 8. Remove smoke generator lead (33) on models with dual-solenoid smoke generation systems. a. Remove self-locking nut (37) and loop clamp (38) for dust detector and smoke generator leads. Discard self-locking nut. b. Remove connectors at smoke generator solenoids (39). c. Cut and remove tie wraps (40) as needed. 33 39 40 37 38 WP 0061 00-8