TM-9-2815-220-24 Maintenance Manual for AVDS-1790-2CA AVDS-1790-DA and AVDS-1790-2DR Engines Download

Page 475 of 1563

TM 9-2815-220-24 WIRING HARNESS REPLACEMENT, STARTER, SMOKE GENERATOR, AND DUST DETECTOR WITH LOW VOLTAGE PROTECTION MODULE TOP MOUNTED (2CA, 2DA) (PART NUMBERS 11655454, 12314619, AND 12354468) 0060 00 INSTALLATION (Continued) 5. Install starter wiring harnesses. a. Install starter main power cable end connectors (62, 63) into mounting bracket (33). Secure with four machine screws (27), new lock washers (28) (item 91, WP 0175), and nuts (29). b. Install low voltage protection module (32) onto mounting bracket (33) with two screws (30) and new lock washers (31) (item 82, WP 0175). Make sure to secure ground wire (53) with one module securing screw (30). 30, 31 (two places) 27, 28, 29 (four places) 33 53 62 63 32 27, 28, 29 (four places) WP 0060 00-21