TM-9-2815-220-24 Maintenance Manual for AVDS-1790-2CA AVDS-1790-DA and AVDS-1790-2DR Engines Download
Page 348 of 1563
TM 9-2815-220-24 GENERATOR REPLACEMENT (300 AMPHERE) 0052 00 INSTALLATION (Continued) 10. Install electrical lead from blower motor harness (11) circuit number 530 (10) and electrical cable (9) on generator terminal "B". a. Secure using self-locking nut (7) with flat washer (8). 11. Install electrical lead 478 (17) on generator terminal "D". a. Secure using self-locking nut (15) with flat washer (16). 12. Install electrical lead 1 (14) on generator terminal "A". a. Secure using self-locking nut (12) with flat washer (13). 14 9, 10, 11 7, 8 12, 13 15, 16, 17 1 9 11 14 17 0 WP 0052 00-10