TM-9-2815-220-24 Maintenance Manual for AVDS-1790-2CA AVDS-1790-DA and AVDS-1790-2DR Engines Download

Page 347 of 1563

TM 9-2815-220-24 GENERATOR REPLACEMENT (300 AMPHERE) 0052 00 INSTALLATION (Continued) 8. Install generator blower (6) electrical connector (23). a. Connect blower (6) electrical connector (23). b. Install ground lead (26) to crankcase and secure using screw (24) with lock washer (25). 24, 25, 26 6 23 9. Connect negative polarity wiring. a. Connect one end of ground strap (20) to crankcase using screw (21) with flat washer (22). b. Connect opposite end of ground strap (20) to generator using self-locking nut (18) with flat washer (19). 20 18 21, 22 , 19 WP 0052 00-9