TM-9-2815-220-24 Maintenance Manual for AVDS-1790-2CA AVDS-1790-DA and AVDS-1790-2DR Engines Download
Page 340 of 1563
TM 9-2815-220-24 GENERATOR REPLACEMENT (300 AMPHERE) 0052 00 REMOVAL (Continued) 2. Disconnect positive polarity wiring. a. Remove self-locking nut (7) with flat washer (8) to disconnect electrical cable (9) and electrical leads (10) and (11). Reinstall self-locking nut and flat washer. b. Remove self-locking nut (12) with flat washer (13) to disconnect electrical lead (14). Reinstall self-locking nut and flat washer. c. Remove self-locking nut (15) with flat washer (16) to disconnect electrical lead (17). Reinstall self-locking nut and flat washer. 14 9, 10, 11 7, 8 12, 13 15, 16, 17 1 9 11 14 17 0 WP 0052 00-2