TM-9-2815-220-24 Maintenance Manual for AVDS-1790-2CA AVDS-1790-DA and AVDS-1790-2DR Engines Download

Page 337 of 1563

TM 9-2815-220-24 GENERATOR REPLACEMENT (650 AMPERE) 0051 00 INSTALLATION (Continued) 14. Install rear oil drain hose (19) to tee (20). 15. Install oil inlet hose (13) to inlet elbow (14) on generator (28). 16. Install oil outlet hose (17) to oil outlet fitting (18) on generator (28). 17. Install vent hose (15) to fitting (16) assuring that orifice fitting (42) is in place. 18. Install J1 and J2 electrical connectors (11, 12) to generator (28). 11 28 12 20 19 17 14 13 18 15 42 16 TEST 1. Setup for ground hop according to the appropriate manual for your application. 2. Start engine and check generator for proper operation. Check that the Battery-Generator indicator needle is in green zone. 3. Check generator oil lines, fittings, and drive adapter for oil leaks. Correct leaks as required. 4. Disconnect from ground hop. 5. Coat all exposed generator terminals with Glyptal (MIL-E-22118) (item 13, WP 0173). END OF WORK PACKAGE WP 0051 00-15 (16 blank)