TM-9-2815-220-24 Maintenance Manual for AVDS-1790-2CA AVDS-1790-DA and AVDS-1790-2DR Engines Download
Page 336 of 1563
TM 9-2815-220-24 GENERATOR REPLACEMENT (650 AMPERE) 0051 00 INSTALLATION (Continued) 13. Connect positive cables (1). a. Honeywell: Connect positive cables (1) to bus bar (5) using screw (2), flat washer (3), and nut (4). 1 1 4 3 2 5 b. Ormat: Connect positive cables (1) to bus bar (6) using screw (2), flat washer (3), and nut (4). 6 2 4 3 1 WP 0051 00-14