TM 9-2815-220-24 GENERATOR REPLACEMENT (650 AMPERE) 0051 00 REMOVAL (Continued) NOTE Early model Honeywell generators were installed with a retaining strap to hold the generator in the cradle. It has been determined that the strap is not required. If the cradle that you removed has the retaining strap, remove and discard it. If your generator does not have a retaining strap, skip to "Exchange Parts." 17. Remove retaining strap (36). a. Loosen T-bolt (37) and remove cradle (24) from generator (28). Using drive punch, drive roll pins (38) attaching strap (36) ends to cradle (24) and discard strap and roll pins. 28 36 38 37 24 36 WP 0051 00-7