TM 9-2815-220-24 GENERATOR REPLACEMENT (650 AMPERE) 0051 00 REMOVAL (Continued) 3. Disconnect two electrical connectors (11, 12) from generator. 18 17 16 15 13 14 12 19 20 11 NOTE Use a suitable container to catch oil that may leak out whenever any oil line is loosened or removed. Cap all tubes, hoses, and fittings to prevent contamination. 4. Disconnect oil inlet hose (13) from fitting (14). 5. Disconnect vent hose (15) from fitting (16). 6. Disconnect oil return hose (17) from fitting (18). 7. Disconnect oil drain hose (19) at rear of tee (20). 27 26 24 21 23 22 7 Ormat 26 26 25 Honeywell 7 25, 26 21 24 19 22, 23 20 8. Remove bracket (21). a. Remove two screws (22) with flat- washers (23) securing cradle (24) to bracket (21). b. Remove two screws (25) with flat washers (26) securing ground straps (7) and bracket (21). c. Remove and retain ground straps (7). d. Remove remaining two screws (27) with flat washers (26) to remove bracket (21). WP 0051 00-4