TM-9-2815-220-24 Maintenance Manual for AVDS-1790-2CA AVDS-1790-DA and AVDS-1790-2DR Engines Download

Page 314 of 1563

TM 9-2815-220-24 STARTER MOTOR REPLACEMENT 0049 00 REMOVAL NOTE Engine models with 650 ampere generators have two ground straps. Engine models with 300 ampere generators have one ground strap. 1. Disconnect starter ground wires. a. Remove hexagon nut (4) and lock washer (5) to disconnect ground strap(s) (6) and two wiring harness cables (7). b. Install hexagon nut (4) and lock washer (5) on starter terminal. c. Remove screw (8) with flat washer (9) to remove ground strap(s) (6) from starter support bracket (10). Retain ground strap(s) for installation. 2. Disconnect starter positive cables. a. Remove hexagon nut (11) and lock washer (12) to disconnect starter positive cables (13) and starter low voltage protective module electrical lead (14). b. Install hexagon nut (11) and lock washer (12) on starter (battery) terminal. c. Remove nut (15) with lock washer (16) from starter to disconnect low voltage protective module electrical lead (17). d. Install nut (15) and lock washer (16) on starter terminal. 6 10 8, 9 17 16 6 15 7 12 13 14 4 5 11 WP 0049 00-2