TM-9-2815-220-24 Maintenance Manual for AVDS-1790-2CA AVDS-1790-DA and AVDS-1790-2DR Engines Download
Page 291 of 1563
TM 9-2815-220-24 ENGINE RUN-IN 0044 00 WP 0044 00-5 BEFORE RUN-IN (Continued) 8. Check for operation of electrical fuel shutoff (9). a. Listen for an audible click while activating the shutoff. 9. Purge fuel filters. a. Open bleeder valve (10) on primary fuel filter (11). b. Open bleeder valve (12) on fuel/water separator filter (13). c. Turn on source supply fuel pump and bleed air from filters. d. Close bleeder valves when fuel flows from both bleeder valves. 9 12 13 WARNING 10 11