TM-9-2815-220-24 Maintenance Manual for AVDS-1790-2CA AVDS-1790-DA and AVDS-1790-2DR Engines Download

Page 1464 of 1563

TM 9-2815-220-24 LOW VOLTAGE PROTECTION MODULE MOUNTING BRACKET REPLACEMENT 0171 00 CLEANING 1. See Work Package 0028 for Standard Cleaning Procedures. INSPECTION All parts must be inspected with care. Replace part if damage or wear exceeds allowable limits. 1. See Work Package 0028 for Standard Inspection Procedures. INSTALLATION 1. Install starter relay mounting bracket (1). a. Apply a small amount of lubricant (item 23, WP 0173) to four bolts (2), (4). b. Position LVPM bracket (1). c. Install wiring harness and clamp (5), secure bracket with two bolts (4), and two new lock washers (3) (item 86, WP 0175). d. Secure two bolts (2) with two new lock washers (3) (item 86, WP 0175). e. Tighten bolts (2) and (4) to 156 to 180 inch-pounds (18-20 Nm). 3 5 2 3 1 4 END OF WORK PACKAGE WP 0171 00-2