TM-9-2815-220-24 Maintenance Manual for AVDS-1790-2CA AVDS-1790-DA and AVDS-1790-2DR Engines Download

Page 1260 of 1563

TM 9-2520-281-34 CAMSHAFT ASSEMBLY, RIGHT BANK, REPAIR 0150 00 REPAIR WARNING Cleaning solvent is mildly toxic. Solvent evaporates and both the fumes and liquid are flammable. Continued contact with solvent can cause skin problems. Ensure there is good airflow when using solvent, and work area is away from heat and flames. Keep fire extinguisher nearby. Do not breathe solvent fumes. Avoid skin contact. See Warning in front of Manual. 1. Remove light scuffing or scoring from camshaft (6) lobes (A) and bearing surfaces (B, C) with crocus cloth (item 9, WP 0173) dipped in cleaning solvent (item 8, WP 0173). 2. Repair damaged threads (D) with a thread chaser tap (item 120, WP 0176). C (7 places) A 6 B D WP 0150 00-4