TM-9-2815-200-35 Maintenance Manual for AVDS-1790-2M AVDS-1790-2A and AVDS-1790-2AM Engines Download

Page 91 of 779

Remove 1. Remove six self-locking nuts (A). 2. Remove and discard generator mounting gasket (B). Install 1. Position new generator mounting gasket (B) on studs. 2. Install, but do not tighten, six self-locking nuts (A). Figure 4-16. Removing or installing generator gasket. Note. It is important that the generator cradle, support, and “U” bolt be installed in a manner that will not disturb generator alinement and still furnish adequate support to minimize vibration. 1. Position the assembled generator cradle, support, and “U” bolt and install four bolts (A) and flat washers. Tighten bolts only until bolt heads engage washers (finger-tight). 2. Install “U” bolt over generator and secure with one clamping bar and self-locking nut (B) and torque tighten. Torque tighten two self-locking nuts (C). 3. Torque tighten four bolts (A) and secure with locking wire as shown in figure 4-12. Figure 4-17. Installing generator support, cradle, and “U” bolt. 4-9