NMWR-9-2815-220 Overhaul Manual for M60 M88 Engine AVDS-1790-2CA, AVDS-1790-2DA, AVDS-1790-2DR Download
Page 767 of 1014
NMWR 9-2815-220 ENGINE ELECTRICAL COMPONENTS OVERHAUL—Continued 0042 00 Table 5. Overhaul Inspection Procedure for Liquid Water Separator (OIP 11668625) (Item 17, Figure 1)—Continued. QA NO. REF. CHARACTERISTIC INSP. REQUISITE REQ. LTR. METHOD OPERATION The control module will energize the load when a conductive liquid (such as water) reaches the high probe, and de-energize the load when the conductive liquid falls below the low probe provided the conductive liquid leaves the low probe within 18± 3 seconds after reaching the high probe. If the conductive liquid remains longer than 18 ± 3 seconds at either probe after reaching the high probe, the control module will de-energize the load and the load will remain de-energized until the control module is reset. Reset of the control module is accomplished by interrupting the input power to the control module for one second or longer. Reset may also be accomplished by causing the conductive liquid to fall below the low probe. END OF WORK PACKAGE 0042 00-11/-12 blank Change 1