NMWR 9-2815-220 GENERATOR AIR DUCTING OVERHAUL—Continued 0038 00 Table 4. Overhaul Inspection Procedure for Air Intake Generator Tube Assembly (OIP 10884037) (Item 13, Figure 1). QA NO. REF. CHARACTERISTIC INSP. REQUISITE REQ. LTR. METHOD 1 Cracks Visual None allowed 2 Fractured or missing Visual None allowed welds 3 Broken, loose, or bent Visual None allowed brackets 4 Damaged threads Visual None allowed 5 Crushed, dented, or Visual None allowed deformed tube ends 6 A Inside diameter Measure 2.850 – 2.890 7 Scratches, nicks, or Visual None allowed gouges 0038 00-7